medical
shower head leak test facility
The machine was designed
to accept manually loaded moulded plastic parts and to leak test
the inductance weld to ensure water did not leak through.
To test the parts at
a differential pressure of 5 bar, a combination of external vacuum
and internal test pressure was used, the maximum leak rate that
was acceptable was
80mm3/sec.
The leak test facility
used manual loading and unloading and achieved typically 120 parts
per hour.
|
|
Medical industry
Nolek S9 Leak Test Instrument with fixture control
Inductance Weld integrity leak test
Auto start on drawer closure
Drawer interlocked on a failure
Single Character fail mark
Clean room environment
Portable
|
|
|
|
If you are currently considering a
medical grade or clean room specification leak test application,
or ant production automation contact TQC to discuss your requirements.
|
TQC Ltd, Hooton Street, Carlton Road,
Nottingham, NG3 2NJ, United Kingdom
Tel: +44 (0)115 9503561
Fax: +44 (0)115 9484642
E-mail: sales@tqc.co.uk
|
|