TQC have designed
and developed a number of leak test systems that utilise a
drawer style fixture. They are manually loaded and unloaded,
with closure of the drawer initiating the leak test. These
machines are known as the TQC Series 20 Leak Test Systems
This example shows
a leak test system for handling a valve block. The system
carries out a series of four leak tests that are initiated
upon the drawer being closed.
The leak test
is performed using a test pressure of 333mbar and a maximum
pressure drop of 4mbar is permissible within 10 seconds.
Pass and fail
results are displayed on an operator HMI. A tamp printer is
included to mark the tested valve block if all four test have
passed. In the event that a test fails, the part is locked
into the fixture and the operator is required to take action.
During the tests,
buttons are automatically pressed on the valve block to fully
function test the unit.
|