leak test equipment
for water valves
Water valves with diameters of 20-100mm can be
leak tested both internally and externally using the:
'differential pressure with water'
technique.
The features of the machine include easily removable tools
for the variable diameters of valves and torque control for closing the valve, and
rotation control at opening and closing of the valve. The control panel is accessible,
with a keyboard for the setting of parameters, such as programmes, times, alarm points and
pressures. The display indicates the test process, pressures and a test result in pascals.
A separate pump stand allows access for maintenance.The measurement pneumatic equipment is
contained within a separate enclosure.
Technical data
| Test piece: |
Water valve, diameter 20-100mm |
| External Pressure: |
40 bar |
| Internal pressure: |
25 bar |
| Leak rate: |
2 drops water per sec |
| Cycle time: |
Approx 70 sec (without handling) |
| Connections: |
Power supply 240/400 V 50H z
|
|
Air approx 6 bar |
|
water and drain BSP/NPT threads
|

There is a pressure tank and return water tank with
requisite filters and valves included, and a sugevac vaccum pump for vaccum pumping of the
valve before filling with water, which provides a high filling rate and eliminates the
fill time before pressure stabilisation. the maximum external test pressure is 25 bar. A
drip tray is placed under the fixture to collect waste water and at the lowest point,
there is a pump for the evacuation of waste water.
Safety
Upon activation of the start button, the valve is
automatically loaded and the protective guard descends, and automatically locks. The guard
may be opened after the test pressure has been reached to allow for visual leak location.
The machine is equipped with clear protective guards and safety switches on three sides to
allow for valve maintenance and filter
exchange.
|
TQC Ltd, Hooton Street, Carlton Road,
Nottingham, NG3 2NJ, United Kingdom
Tel: +44 (0)115 9503561
Fax: +44 (0)115 9484642
E-mail: sales@tqc.co.uk
|
|