leak test equipment
for water valves
Technical
data
|
Test piece:
|
Water
valve, diameter 20-100mm |
|
External Pressure:
|
40 bar |
|
Internal pressure:
|
25 bar |
|
Leak rate:
|
2 drops
water per sec |
|
Cycle time:
|
Approx
70 sec (without handling) |
|
Connections:
|
Power
supply 240/400 V 50H z |
|
Air approx
6 bar |
|
water
and drain BSP/NPT threads |
|
Water valves with diameters
of 20-100mm can be leak tested both internally and externally
using the 'differential pressure with water' technique.
The features of the machine
include easily removable tools for the variable diameters
of valves and torque control for closing the valve, and rotation
control at opening and closing of the valve. The control panel
is accessible, with a keyboard for the setting of parameters,
such as programmes, times, alarm points and pressures. The
display indicates the test process, pressures and a test result
in pascals. A separate pump stand allows access for maintenance.The
measurement pneumatic equipment is contained within a separate
enclosure
|
|
There is
a pressure tank and return water tank with requisite filters
and valves included, and a sugevac vaccum pump for vaccum
pumping of the valve before filling with water, which provides
a high filling rate and eliminates the fill time before pressure
stabilisation. the maximum external test pressure is 25 bar.
A drip tray is placed under the fixture to collect waste water
and at the lowest point, there is a pump for the evacuation
of waste water.
Safety
Upon activation of the start
button, the valve is automatically loaded and the protective
guard descends, and automatically locks. The guard may be
opened after the test pressure has been reached to allow for
visual leak location. The machine is equipped with clear protective
guards and safety switches on three sides to allow for valve
maintenance and filter exchange.
|
|
|