Please call: +44 (0)115 950 3561

Leak Testing Method

Leak testing equipment including a pressure gauge, pneumatic fittings and a test fixture with valves

How to select the right leak testing method for your application

Choosing leak testing equipment starts with the application, not with a preferred instrument. The required leak limit, part volume, test pressure, temperature, production cycle time and whether the leak needs to be located all influence which method is appropriate.

Pressure or vacuum decay, mass flow, tracer gas and bubble testing each solve different problems. The best method is the one that can measure the required condition reliably within the production process without adding unnecessary sensitivity, cost or cycle time.

Start with the leak requirement

Before comparing methods, define what a failed part actually means. The specification should state the maximum acceptable leakage, test pressure, test medium and any relevant temperature conditions. It should also distinguish between a simple pass/fail requirement and a need to find the exact leak location.

The test method then needs enough measurement capability to enforce that requirement with a sensible margin. Selecting a highly sensitive technique for a coarse leak limit can add complexity without improving the product.

Air decay leak testing

In air decay leak testing, the part is pressurised or evacuated, isolated and monitored for a pressure change over a defined period. The method is widely used because it is straightforward to automate and does not consume a tracer gas.

It performs best when part volume is controlled and the test environment is thermally stable. Warm parts, drafts or changing temperatures can influence pressure and create measurement noise, so stabilisation time and fixture design are important.

Vacuum decay and mass flow

Vacuum decay uses the same general principle in reverse: the part or chamber is evacuated and the system monitors for a pressure rise. It can suit products that cannot be safely pressurised or applications where ingress is the concern.

Mass flow testing maintains a controlled pressure and measures the make-up flow required to replace leakage. It can be useful for larger volumes or where part-to-part volume variation makes pressure-decay measurement less convenient. The instrument and fixture still need to be matched to the expected flow range and production conditions.

Tracer gas and helium leak testing equipment

Tracer gas methods are used when the required sensitivity is beyond what an air-based method can achieve or when the application specifically calls for tracer-gas testing. Helium can be detected selectively, allowing very small leaks to be measured and, with sniffing techniques, located.

The trade-off is greater system complexity. Helium leak testing equipment can involve vacuum systems, gas handling and controls that increase capital cost and may affect cycle time. The method is therefore most appropriate where the product requirement justifies that additional capability.

Bubble testing still has a role

A bubble or dunk test is simple: a pressurised part is submerged or a leak-detection solution is applied and bubbles reveal the leak location. It is useful for development work, low-volume checks and fault-finding after another method has identified a failed part.

For high-volume production, it is harder to automate, depends on operator observation and does not provide the same quantified digital result as dry automated methods.

Do not overlook fixturing and production integration

Reliable leak testing equipment depends on more than the instrument. Seals, end plugs and clamps must engage consistently, otherwise fixture leakage can be mistaken for product leakage. The test also has to fit within the available cycle time and handle failed parts in a controlled way.

Where traceability is required, the measured result should be linked to the product identity rather than recording only a generic pass/fail. Trend data can then help identify gradual process drift before the reject rate changes sharply.

Choose the method from the process conditions

Pressure decay is often a good starting point for stable parts and moderate requirements. Mass flow can help where volume or thermal variation is more challenging. Tracer gas is appropriate when very high sensitivity or leak location is essential. Bubble testing remains useful where simplicity and location matter more than automated measurement.

TQC’s leak testing equipment and solutions cover different methods so selection can be based on the product requirement rather than a single preferred technology.

Talk to TQC about your leak test application

If you are specifying a new leak test or reviewing inconsistent results from an existing process, TQC can help define the test conditions, method, fixture and production integration. Explore our leak testing solutions and contact the engineering team to discuss your application.